Cart 0

30 kW Diesel Generator

  • SKU # AGi30P
  • $16,675.00

Commercial | Industrial | 30,000 Watt Diesel Generator

Perkins Turbo Diesel Powered

Generator Overview

In commercial / industrial applications, this size generator is one of our most popular. One of the reasons it is so popular is the engine we use. It is a Turbo Diesel Engine by Perkins (a Caterpillar owned company)   Turbo diesel engines are popular in industrial and commercial generators for some of the following reasons;

  • Increased output power
  • More reserve power
  • Lower fuel consumption
  • More efficient cooling system and air flow
  • Less noise and vibration
  • Ability to operate at higher altitudes. 

AURORA can customize this generator platform to fit your needs better if required.  Doing so at the manufacturing level can save you money and help you avoid the cost of aftermarket retrofitting accessories.

Main Features

  • Designed to work full or part-time
  • 120/240 Volt Single Phase 60 Hz. 
  • Optional 3 Phase 208 and 480 Volt
  • Advanced Generator Controller
  • Tough steel welded base frame that incorporates for lift channels for easy lifting
  • Central Top Lifting Point
  • Heavy duty canopy enclosure
  • Large exhaust system
  • North American Built 
  •  Integral Fuel Tank
  • Advanced generator controller by DynaGen
  • Optional Cold Weather Package (Snow Hood, Block Heater, Space Heater Dampers and Alarms for harsh operating conditions
  • Download Dimensional Drawings
General Specifications
Model AGi30P
Type Diesel

30 kW Standby Generator
60 Hz., 1800 RPM Liquid Cooled
Single Phase, 1.0 Power Factor
Automatic Voltage Regulated
120 Volt - 250 Amps
240 Volt - 125 Amps

Also Available in 3 Phase 208, 480 and 600 Volts

Sound Level 65 dB @ 23 Feet
Dimensions L x W x H 59" x 33" x 46"
Weight 1,350 Lbs
Country of Origin Made in Canada
Approvals CSA SPE-1000

Generator Controller - Features & Functions

For clear generator instrumentation, protection and control, this generator uses a DynaGen TG350 Controller.

DynaGen Generator Controller TG350

Main Features

  • Designed for Extreme Shock and Vibration
  • Easy to use front panel buttons
  • Manual or Automatic Starting
  • Exerciser Clock
  • Maintenance Counter
  • Passcode Protected
  • Automatic shutdowns and warnings
  • Pre-heat and post-heat timers
  • 150 Event Log
  • Fuel level display and alarm
  • Voltage display and alarm
  • Simple two-wire auto start - Easily connect to remote start using a transfer switch, off-grid power inverters, controllers or remote starters
  • Auto start on low battery and/or other sensors
  • Front panel trim feature for sensor adjustments
  • 5 Year Manufacture Warranty
  • Load Monitoring (TG410 Model Only)

There are two versions of this controller. The TG350 is included. The TG410 is an optional upgrade. With the TG410, current sensors can be used to monitor generator loads / power consumption.  One other feature is the "Can Bus" port. Like a vehicles ODBII connector, it lets you communicate with the generator for remote monitoring and control.  You will need the TG410 if you wish to use this in the future. 

Monitoring Functions

Engine Temperature

Engines normally use an engine coolant temperature switch and oil pressure switch. They only turn on or off when there is a fault and do not let you read actual engine temperature. We feel it is important to know how hot the engine is running and detect an issue before it becomes necessary to shut down the engine. For this reason, we include an additional sensor to monitor the coolant temperature so that if it ever reaches a warning level it will notify you and log the condition. If a critical level is reached the generator controller will shut down the generator. For added protection the generator controller is additionally set to log four set points. High and Low warning levels and failure levels.

Radiator Coolant Level

Aurora Generators are equipped with this additional sensor in the radiator to eliminate low coolant level. It is engineered from high quality corrosion-resistant materials to accurately and reliably alert the generator controller to low coolant level and shut down the generator. Engine temperature sending units/sensors alone are supposed to detect overheating. However, if coolant level is low, temperature sending units/sensor's cannot measure the coolant temperature. When coolant level in an engine is low, the cooling system cannot adequately remove excess heat from the engine.

Oil Pressure

Oil pressure is an important factor in the longevity of an engine. Oil pressure ensures that the metal parts moving in the engine, never touch each other. An oil pressure switch is standard on every engine / generator. Should oil pressure ever be lost, the engine controller will shut down the motor.

For some installations, customers maybe required to keep track and log the actual oil pressure.  For this, another optional oil pressure sending until is available. Knowing the actual oil pressure will help you know if the engine has warmed up, oil is flowing as it should, filters are not plugged, oil is breaking down or engine wear is happening and service is required.  

Fuel Level

Aurora fuel tanks have a fuel level sensor installed. The controller can display a warning when fuel level is low. The generator can be set to shut down before its empty. Shutting down before it is empty helps prevent difficult starting caused by air that enters the fuel pump and fuel injectors.

Generator Output

The generator controller monitors the power generated by the alternator. From the output voltage it can determine the engine speed in rpm, alternator frequency and voltage output are correct.  If they start to fall outside of set normal ranges, it will warn you and log it for future reference. Any critical errors will cause the generator to safely shut down. 

Controller Specifications

Model TG350 Standard Generator Controller
TG410 Optional Upgrade
Operating Voltage 5.5 to 38 VDC continuous.
Cranking dropouts to 0VDC
for 50mS, also meets SAEJ1113-11
Standby Current Draw 50 MA
Protection Reverse battery & overload protected
Operating Temperature -40c - + 70c (-40 - +158F)
Vibration and Shock Meets or exceeds SAEJ1455
Electromagnetic Compatibility Meets or exceeds MIL-STD-461E Conducted Emissions
Configurable Switched Inputs 5
Configurable Switched Outputs 4
Warranty 5 Years

Diesel Engine

This generator uses a small and compact yet powerful four-cylinder turbo diesel engine from Perkins. Perkins engines offer exceptional performance and long life.  Perkins engines are radiator cooled, slow turning engines that can run full or part-time.  Perkins engines require less oil, air, and fuel filter changes (every 500 hours depending on load factor). The low fuel consumption and ultra-compact engine offer all the customer benefits experienced from larger engine sizes. The engine has a proven record and has been in use worldwide for many years in providing power for homes, business and construction equipment.

Engine Specifications 
Make/Model Perkins 404D-22TAG
Glow Plugs Included
Engine Speed 1800
Number of Cylinders 4
Aspiration Turbocharged
Combustion System Indirect Injection
Compression Ratio 23.3:1
Bore and Stroke 84 x 100 mm (3.3in x 3.9in)
Displacement 2.2 liters (135 in³)
Cooling System Water Cooled
Coolant Capacity 9.3L (2.4gal US)
Oil Capacity 10.6 L (2.8 gal US)
Oil and Filter Changes 500 Hours depending on load factor.
Starter 12 Volt
Alternator 65 Amp
Starter Battery 850 CCA
Perkins Engine Warranty 2 Year 3000 Hour - 5 Year Optional


Aurora industrial class alternators are highly reliable and produce clean, stable power even in harsh conditions. Automatic Voltage Regulated to 0.5% precision. The alternator is brushless and requires no maintenance. The generator head is directly driven by a heavy engine flywheel. The large rotating mass helps to reduce fluctuations in power when heavy loads are applied.

Model SM180E
Type Brushless Automatic Voltage Regulated
Voltage Regulation ±0.5%
Rated Output 120/240 Volt Single Phase 30,000 Watts Standby
Insulation Class H
Warranty 5 Years

Canopy Enclosure

AURORA Acoustic Weather Enclosure is uniquely designed to be durable, compact, aesthetically pleasing and to reduce noise while maintaining proper ventilation.


  • All Stainless Steel Fasteners
  • Corrosion resistant galvanized steel construction
  • Tough neutral grey power coated finish
  • Acoustic foam insulated to help absorb sound and reduce vibrations
  • Hinged and lockable doors with weather stripping 
  • Top Lifting Point

Fuel Tank

AURORA offers a few fuel tank options. 

  • Day Tank - Internal 45 Litre / 12 Gallon
  • Sub Base - 450 Litre / 100 Gallon Tank
  • Standalone - 450 Litre / 100 Gallon UL Double Wall Tank
  • Standalone - 1100 Litre / 250 Gallon UL Double Fuel Tank 
  • Mobile - 225 Litre / 50 Gallon UL Mobile Fuel Tank
  • Mobile - 450 Litre / 100 Gallon UL Mobile Fuel Tank

Generator Options

TG410 Controller Upgrade  $149.00 USD  $190.00 CDN
Current Load Sensing  $179.00 USD  $229.00 CDN
Battery Charger  $176.00 USD  $225.00 CDN 
Coolant Block Heater $185.00 USD $235.00 CDN
Remote Monitoring $635.00 CDN
Wireless Remote Control $230.00 USD $295.00 CDN
Solar Battery Charger $63.95 USD $81.00 CDN
Battery Cables (OEM) $32.00 USD $40.00 CDN
4" Riser Feet $155.00 USD $193.00 CDN
Snow Hood call call
Damper call call
Space Heater call call
Spare Perkins OEM Filters Click for Perkins Filters  Click for Perkins Filters

We Also Recommend